– 44 –
9) Adjustment of released presser height
1. If the dimensions is not 25 ± 1 mm unlike the drawing, loosen the nut
securing the clamp foot cylinder and adjust the screwing amount
into the elevating block .
10) Positioning adjustment of the flap presser
1. If the dimensions is not 6.5 ± 0.5 mm unlike the drawing, loosen the
setscrew and adjust the position of the flap presserr .
For this adjustment, however, never fail to adjust the parallelism for
the folding plate and the flap presser .
11) Positioning adjustment of flap scale and flap stopper
1. In conjunction with the flap length, loosen the setscrew of the flap
scale for adjustment
2. The flap stoppers (A) and (B) used to set up the flap materials
shall be mainly adjusted by loosening the setscrew according to
the condition of pattern arrangement for the serge back materials
and flap materials.
Adjustment Procedures Results of Improper Adjustment

Table of Contents