– 51 –
(1) How to set the counter
Selecting the counter setting
<Mode screen>
Setting the type of counter, current value of counter and preset value for counter
<Counter type selection screen>
Type of counter
Current value of
counter
Preset value for counter
Press
on the mode screen. Select "02
Counter setting". Press
to display the
counter setting screen.
1. The type of counter can be selected by pressing
.
2. Select the target item by pressing
.
The value of the item you have selected can be
changed by pressing
.
If
is pressed while the current value
or set value of the sewing counter is selected,
the current value or set value can be reset to "0"
(zero).
3. When
is pressed, the screen returns
to the mode screen. When
is pressed
again, the screen returns to the sewing screen.
Type of counter Setting item Setting range
Sewing counter
(Count-up counter) (Count-down counter)
Current value 0 to 9999
Set value 0 to 9999
Pitch time counter
Pitch time
1.0 to 999.9
(Unit: Second)
Counter unused
(No setting item)