Table 27: QFX5200 Switch Environmental Tolerances
(Connued)
Descripon Model Tolerance
Temperature QFX5200-32C and
QFX5200-32C-L
• Normal operaon ensured in temperature range
of 32° F through 104° F (0° C through 40° C)
• Nonoperang storage temperature in shipping
container: –40° F through 158° F (–40° C
through 70° C)
QFX5200-48Y
• Normal operaon ensured in temperature range
of 32° F through 113° F (0° C through 45° C) for
AFO models, 32° F through 104° F (0° C
through 40° C) for AFI models
• Nonoperang storage temperature in shipping
container: –40° F through 158° F (–40° C
through 70° C) for both AFO and AFI
Seismic QFX5200 all models Designed to comply with Zone 4 earthquake
requirements per NEBS GR-63-CORE, Issue 3.
NOTE: Install QFX Series devices only in restricted areas, such as dedicated equipment rooms
and equipment closets, in accordance with Arcles 110-16, 110-17, and 110-18 of the Naonal
Electrical Code, ANSI/NFPA 70.
General Site Guidelines
Ecient device operaon requires proper site planning and maintenance and proper layout of the
equipment, rack or cabinet, and wiring closet.
To plan and create an acceptable operang environment for your device and prevent environmentally
caused equipment failures:
• Keep the area around the chassis free from dust and conducve material, such as metal akes.
67