Table 28: Physical Specicaons for the QFX5200
Product SKU Height Width Depth Weight
QFX5200-32C and
QFX5200-32C-L
1.72 in. (4.3 cm) 17.36 in. (44.1 cm) 20.48 in. (52 cm) 23.5 lbs (10.66 kg)
QFX5200-48Y 1.71 in. (4.34 cm) 17.25 in.
(43.81 cm)
20.27 in.
(51.48 cm)
30.00 lbs
(13.60 kg)
Site Electrical Wiring Guidelines
Table 29 on page 71 describes the factors you must consider while planning the electrical wiring at
your site.
WARNING: You must provide a properly grounded and shielded environment and use
electrical surge-suppression devices.
Averssement Vous devez établir un environnement protégé et convenablement mis à
la terre et uliser des disposifs de parasurtension.
Table 29: Site Electrical Wiring Guidelines
Site Wiring
Factor
Guidelines
Signaling
limitaons
If your site experiences any of the following problems, consult experts in electrical surge
suppression and shielding:
• Improperly installed wires cause radio frequency interference (RFI).
• Damage from lightning strikes occurs when wires exceed recommended distances or pass
between buildings.
• Electromagnec pulses (EMPs) caused by lightning damage unshielded conductors and
electronic devices.
71