Reinstall Components
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis. For more information about ESD,
see the SRX3600 Services Gateway Hardware Guide.
2. Slide each component into the chassis evenly so that it does not become stuck or
damaged.
4. Tighten the captive screws or lock any levers for each component installed.
NOTE: Make sure that all empty slots are covered with blank panels before
operating the services gateway.
Proceed to “Step 4: Connect the Grounding Cable” on page 13.
Step 4: Connect the Grounding Cable
1. Verify that a licensed electrician has attached the cable lug, provided with the services
gateway, to the grounding cable.
2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect
the strap to an approved site ESD grounding point. See the instructions for your site.
3. Ensure that all grounding surfaces are clean and brought to a bright finish before
making grounding connections.
4. Connect the grounding cable to a proper earth ground.
5. Disconnect the ESD grounding strap from the site ESD grounding point.
6. Connect the ESD grounding strap to one of the ESD points on the chassis. For more
information about ESD, see the SRX3600 Services Gateway Hardware Guide.
7. Place the grounding cable lug over the grounding point. The grounding point is sized
for M5 screws. See Figure 12 on page 14.
13Copyright © 2011, Juniper Networks, Inc.
Reinstall Components