Loading...
16 JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
2.1 Hardware introduction
2.1.1 Overall hardware description
All internal and external main connections can be seen in the illustration below.
P+
CVI
P+
P-
P-
5V
O+
IN1
IO
-
O1
Rx1P
Rx0P
Rx1N
Rx0N
Tx1P
Tx0P
Tx1N
Tx0N
Tx
Rx
O1
Fx4
IO1 4-
Fx1 3-
RX
O2
A1/B1
A2/B2
TX
GND
GND
4 Inputs
4
3
4
2 Outputs
RS232
serial interface
Control
core
incl
8Mb RAM
4Mb Flash
Power supply for the module
“PWR”
Power supply
MAC400/800: +24V
“I/O”
Digital inputs and outputs
Voltage range 5-28 (32)V
“L/A IN”
Primary
EtherNet
Interface
M12 female
connector
“L/A OUT”
Secondary
EtherNet
Interface
M12 female
connector
TT3003GB
MAC00-Ex4 expansion module
Basic MAC motor
(MAC400 or 800)
Power supply
Internal power supply
(processor and encoder)
Multifunction I/O1
(setup as “serial data”)
Multifunction I/O2
High speed sync. 0/1
Optional I/O use
Internal COM
Status outputs
Asynchronous
interface (5V)
AIN1
AIN2
Analogue inputs
AIN1=Zero search input
±10V nom. or up to 32V
8
2
2
2
2
3
3
3
3
4
4
4
4
6
5
5
7
1
1
1
1
See note1
See note1
See note1
See note1
Note1: These signals are internally avilable. Custom hardware can be made
for OEM appl. with other connectors in order to make the signals available.
Contact your JVL representative for more information.
Optocoupler
Isolation zone 2
Each isolation zone do not have galvanic contact with any other circuitry.
Isolation zone 3
Isolation zone 4
Only MAC