180 JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
8.2 Commisioning
8.2.1 Indicators LED description
The LED's are used for indicating states and faults of the Sercos
®
module. There is one
power LED, two link/activity LED's (one for each Ethernet connector), and 2 status
LED's.
LED indicator descriptions
LED Text
MAC / MIx
Colour Constant off Constant
Orange
Constant
Green
Constant
Red
Flickering
L/A IN /
L2
Green No valid Ethernet
connection.
- Ethernet is
connected.
- Activity
on line
L/A OUT /
L3
Green No valid Ethernet
connection.
- Ethernet is
connected.
- Activity
on line
STATUS /
L1
Multi color
- See table below -
ERROR /
ERR
Multi color Sub Device
not active
Parameteri-
zation level
Operating
level
Class 1
Diagnostics
error
-
PWR /
PWR
Green Power is not
applied.
Power is
applied to
both motor
and module.
- - Power is ap-
plied to module
but no com-
munication with
motor.
Notes:
Flickering: Rapid flashing with a period of approx. 50ms (10 Hz).
TT3010-02GB
Error indicator
Hardware serial number
Hardware serial number
General status
indicator
MAC Module Indicators
and label overview
MIS Motor Indicators
and label overview
MAC address
Line activity
indicators
Error indicator
Power indicator
Line activity indicator (CN2)