JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors 181
8.2 Commisioning
STATUS/L1 led description.
8.2.2 Mechanical installation
The MAC00-ES4x Sercos
®
module and the MIS/MILxxxES Sercos
®
motor from JVL are
both equipped with two M12 Ethernet ports, enabling the possibility for line and ring
structures. The network cables must be connected to the two M12 connectors marked
"L/A IN" and "L/A OUT" on the MAC motor module, and CN2 and CN3 at the MIS/MIL
motors.
Figure1:Redundantringtopology.
Color 1 Color 2
(when
flashing)
State Description Comments
Green Green On CP4 (no error) Normal operation, cyclic is running.
Green Orange Flashing HP0 - HP2
Hot-plug modes.
Flashes once for HP1, twice HP2,
continuously for HP0
Green Dark Flashing Loopback -
Red Red On Communication error.
See Diagnosis (errors and warnings),
page 202 for error codes.
Red Green Flashing
Communication error
(MST Losses)
See Diagnosis (errors and warnings),
page 202 for error codes.
Red Orange Flashing Application error
See Diagnosis (errors and warnings),
page 202 for error codes.
Red Dark Flashing Watchdog error Application is not running
Orange Orange On CP0 -
Orange Green Flashing CP1 - CP3
Flashes once for CP1, twice CP2,
three times for CP3.
Orange Dark Flashing Identification -
Dark Dark Off
No Sercos
®
communication
-
TT3115-01GB
Sercos
Master
Motor
with
Sercos
module
Motor
with
Sercos
module