JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors 59
3.5 CiA® DSP-402 drive profile
3.5.6 Supported values of quick stop option code (object 0x605A)
Bit Meaning Supported
0Disabledrivefunction Yes
1SlowdownonslowrampandtransitintoSwitchOnDisabled Yes
2SlowdownonquickrampandtransitintoSwitchOnDisabled Yes
3SlowdownoncurrentlimitandtransitintoSwitchOnDisabled No/Sameas2
4SlowdownonvoltagelimitandtransitintoSwitchOnDisabled No/Sameas2
5Slowdown
onslowrampandstayinquickstopactive Yes
6Slowdownonquickstoprampandstayinquickstopactive Yes
7Slowdownoncurrentlimitandstayinquickstopactive No/Sameas6
8Slowdownonvoltagelimitandstayinquickstopactive No/Sameas6