805.33
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 03: Current Alarm Messages, Continued
Alarm
message table
with cause and
remedy con't
Alarm Cause Remedy
Rate Less than
Setpoint Alarm
Actual mass flow rate
is less than the
setpoint by the
Massflow - Alarm
Limit, or that the
motor has stopped.
see K-Cdr page
Mcn.04
Be sure that feeder is
discharging. Make
sure limit setting is
not tighter than the
feed system can
deliver. Check with
Drive Command
alarms and verify that
motor runs with
speed feedback.
Refill Timer Expired
Alarm
Actual refill time, in
automatic refill, has
taken longer than the
refill timer setpoint
allows. See K-Cdr
page Mcn.02
Check refill valve for
operation and refill
hopper for adequate
material. Recheck
actuation time.
I-O Board Failure
Alarm
Failure between
K-Cdr Controller and
I-O Pc boards.
Check hardware in
K-Cdr for correct
operation. Refer to
led chart and
hardware description.
Rate Greater than
Setpoint Alarm
Actual mass flow rate
is greater than the
setpoint by the
Massflow + Alarm
Limit, see K-Cdr page
Mcn.04.
Check for flooding of
material. Check to see
if setpoint is rapidly
changing. Make sure
limit setting is not
tighter than the feed
system can deliver.