805.34
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 03: Current Alarm Messages, Continued
Alarm
message table
with cause and
remedy con't
Alarm Cause Remedy
Scale/SFT# "xx"
Overrange Alarm
The scale or
individual SFT as
identified by the "xx"
is in overrange.
SFT has weight on it
greater than its
capacity. Remove
weight from the scale
or SFT.
Scale/SFT# "xx"
Underrange Alarm
The scale or
individual SFT as
identified by the "xx"
is in underrange
condition.
The gross weight
reading is below zero
by more than the Net
Weight Low(-)value.
Generally a failure
condition in the
transducer or scale
system. In a B scale,
the counterweight
has shifted. Binding
or forced unloading
of the SFT may also
result in this problem.
Weight Processor
Failure Alarm
Controller is not
receiving a weight
signal from SFTs to
which it is connected.
Many problems can
cause this situation.
An SFT failure, a
Scale Interface Pc
failure, a power
failure to the SFT or
scale Interface Pc
board.