805.36
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 03: Current Alarm Messages, Continued
Feeder
stopped by
conditions
The last line on the display shows how the feeder was last stopped.
Here is a listing of the causes as indicated.
Message Meaning
Board Reset Message
The K10S controller pc board is
in reset.
Run Disable Message The Run Enable Input is
preventing the unit from
running.
Stop Bit Message
The feeder was stopped by the
stop bit input.
Alarm Shutdown Message The feeder was stopped by the
alarm shutdown input.
Local Display Message The feeder was stopped by stop
button on the local display.
External Display Message
The feeder was stopped by stop
button on the remote display.
Zero Setpoint Message No setpoint is present.
Drive Command Low Message Drive command is below 1%.
Motor Drive Failure Message Motor is not running when told
to run with adequate drive
command. With serial connected
motor controllers, this message
will occur if the drive is powered
down while running or if the
drive's safety interlock is opened
while running.