805.53
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 06: SFT Programming, Continued
Page 06
variable list
con't
Variable Name Edit? Description
SFT Type Code This value identifies the gross scale
range of the selected SFT
automatically. Ranges will be from
6 Kg to 1500 Kg.
SFT Configuration ` By pressing the F3 key, you will
cause a "Poll" to result and thus
identify the connected SFTs. To
connect an SFT, its address must be
preset to "0".
SFT Failure Codes
"f" = SFT failure of its internal
parts. A vibrating wire or other
malfunction has occurred. The
SFT is still communicating with
the controller.
"t" = Timeout. The SFT is not
communicating with the
controller. The reasons are many.
"?" = Incorrect response from
SFT.
" - ' = No SFT at the location
indicated.
Continued on next page