805.58
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 07: Feeder Setup Data, Continued
Page 07
variable list
con't
Variable Name Edit? Description
Speed Pick-up Gear
Teeth
` If a liquid or screw feeder is used
with a motor that has a speed pick-
up type of tachometer, this entry
scales the RPM display to read
correctly. Look to the feeder
specification sheet to determine
this entry.
Range of Values
0 to 500
Default value is 120
Total Gear Reduction ` This is always 1. Anything else will
cause the Motor RPM to be
incorrect.
Range of Values
0.2 to 100
Default valu e is 1.000
Continued on next page