805.59
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 07: Feeder Setup Data, Continued
Page 07
variable list
con't
Variable Name Edit? Description
Feeder Mode `
Local <
Ratio
Direct
Line 1
Line 2
Line 3
Line 4
Local <
Ratio
Direct
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
Line 7
Determines whether a feeder is to
be operated by itself or a part of
Lines 1 to 7. This entry determines
where the controller's setpoint
comes from. Refer to the section on
Control Modes to learn how each
selection affects the function of the
controller. Default value is " Local".
Full Scale Drive
Command
` This value determines the
frequency output for drive
command when the Drive
Command reads 100%. The default
for this entry is 10000 Hz and is
normal for most applications.
Range of Values
1,000 Hz to 40,000 Hz
Default value is 10,000 Hz
Continued on next page