EasyManuals Logo

Kaba Saflok SYSTEM 6000 User Manual

Kaba Saflok SYSTEM 6000
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
System6000
TM
ReferenceManual_Section6
© SAFLOK Page23of34 06/11
024 PIPassMaster:Inordertochangethevalidpassnumbers,thepasscriteriamustalsobe
programmedin.ContactSAFLOKforassistance.
025 PIPassMaster:Ifthekey’spasscriteriaequals0,allthepassnumbersmustequal0.Contact
SAFLOKforassistance.
026 PIPassMaster:Ifthekey’spasscriteriaequals1,allthepassnumberscannotequal0.Contact
SAFLOKforassistance.
PILevelProgramErrorsinProgramCycle
Code Description
027 PILevelProgram:IfPIkey’scurrentprogramgroupnumberdoesnotequal0,thenitmustequal
thekeytype’sprogramgroupnumber.ContactSAFLOKforassistance.
028 PILevelProgram:Ifthekeytype’sprogramgroupequals0(nonoperating),thePIkeymust
programintheoperation.ContactSAFLOKforassistance.
029 PILevelProgram:PIkeycannotprograminthefunctionwithoutprogramminginthesub
functionandadditionalfunctioninformation.ContactSAFLOKforassistance.
030 PILevelProgram:PIkeyfunctiongreaterthen5isinvalidorPIkeyisnotprogramminginthe
functionanditsfunctiondoesnotequalkeytype’sfunction.ContactSAFLOKforassistance.
031 PILevelProgram:PIkeyhasinvalidvalueforthesubfunctionoradditionalfunctionbasedonthe
key’sfunctionvalue.ContactSAFLOKforassistance.
PIKeyMasterErrorsinProgramCycle
Code Description
032 PIKeyMaster:Add/Change/DeleteThePI keyisforakeylevelwithoperationequals0(non
operating)orequals7(pass)whichdoesn’thaveindividualkeys.ContactSAFLOKforassistance.
033 PIKeyMaster:Add/Change/DeleteThePIkey’sNewKeyDate/Timefieldshaveinvalidvalues.
ContactSAFLOKforassistance.
034 PIKeyMaster:Change/DeleteThePIkeyrecordnumberisnotinthelocksoitcannot
change/deletethekey.ContactSAFLOKforassistance.
035 PIKeyMaster:Change/DeleteThePIkeyisnotprogrammingoroverridingthekey’sNewDate
andthekey’sNewDatedoesn’tmatchthelock’skeydata.ContactSAFLOKforassistance.
036 PIKeyMaster:AddThePIkey’srecordnumberisalreadyinthelocklevelsoitcannotbe
added.ContactSAFLOKforassistance.
037 PIKeyMaster:Add/ChangeThelevelhasabatchoperationandthePIkeycannotadd/changea
SequenceNumbergreaterthan32.ContactSAFLOKforassistance.
038 PIKeyMaster:Change/DeleteThePIkeyisnotprogrammingoroverridingthekey’sSequence
Numberandthekey’sSequenceNumberdoesnotmatchthelock’skeydata.ContactSAFLOKfor
assistance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kaba Saflok SYSTEM 6000 and is the answer not in the manual?

Kaba Saflok SYSTEM 6000 Specifications

General IconGeneral
BrandKaba
ModelSaflok SYSTEM 6000
CategoryControl Systems
LanguageEnglish