System6000
TM
ReferenceManual_Section6
© SAFLOK Page20of34 06/11
6.8DiagnosticsErrorCodes
LPIProgrammingErrors
Ifanerroroccurswhenalockisbeingprogrammed,theLPITerminalwilldisplaythefollowingscreenindicatingan
errorcodeontheErrorLine:
***LPIERRORXXX***
ErrorOccurredWhenSendingKeyLevelxx,Typeyy,xxxxxxxxxx
LOCKANDPROBECOMMUNICATIONSHAVEBEENTERMINATED
(PRESSAnyKey)
ThecodenumberindicatedontheErrorLineisthesameasthatusedbyLEDDiagnosticsandyoucanrefertothe
codesinthissectionforinformationabouttheproblem.ForLPIProgrammingerrors,youwillneedtocontact
SAFLOKforassistance,andyourSAFLOKrepresentativewillneed thiserrorcodeinformation.
MostCommonDiagnosticsErrorCodes
ThefollowingerrorcodesaremostlikelytoappearwhenperformingLEDDiagnostics:
Code Description
113 AllKeys:Thekeyisnotvalidinthecurrentlockmodeorcycle.IfLEDDiagnosticsison,turnoff.
Lockistypicallyinaninvalidmode.RefertoSection3,InvalidModeIndicatorsforadditional
information.ThiscodemayalsoappearifyouuseStandardorDisplaykeyswhenthePPKorSPK
LEDsareflashing.
117 Standard,Special,PPKandSPKKeys:thelockisinshutdowncyclebecause10ormoreinvalid
keyswereused.Avalidkeymustbeusedtoterminateshutdownmode.
122 StandardKeys:Lockisnon‐operatingforthiskeytype.Thekeydoesnotbelongtothislock.
123 StandardandSpecialKeys:Keyisnotmasteredintothelock.Thekeydoesnotbelongtothis
lock.
127 StandardKeys:Keydoesnothaveoneofthe12validPassnumbersrequiredforthePass
function.
128 StandardandSpecialKeys:Keyisanoldkey;itsnewkeydateisearlierthanthelock’skeydata.
Replacethekeywithacurrentornewkey.
129 StandardandSpecialKeys:Keyisanoldkey;itsnewkeytimeisearlierthanthelock’skeydata.
Replacethekeywithacurrentornewkey.
134 StandardandSpecialKeys:Keyisanoldkey:Keytypehaslimitedsequencerange(1‐15)but
key’ssequencenumberisolderthanthelock’skeydata.Replacekeywithacurrentornewkey.
Useare‐sequencekeyifnecessary.