EasyManua.ls Logo

Kaba Saflok SYSTEM 6000 - Pass Feature; Invalid Keycard Shutdown; LED Diagnostics; Low Battery and Clock Reset

Kaba Saflok SYSTEM 6000
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System6000
TM
ReferenceManual_Section4
SAFLOKLockFeatures(continued)
PassFeature
Thisfeatureisusedforspeciallockssuchaspooldoors,elevatorsorlimitedaccessdoors.Certaintypesofkeycards
canbeprogrammedas“pass,”allowingallkeycardsforthattypetoactivatethelockingmechanism.The“pass”
featurecanbeprogrammedinseveralways:
PassonPropertyNumberTheselockswillallowanykeycardmadeatthepropertytofunctioninthe
locks.
PassNumbersSpeciallocks(lounge,elevator,etc.)canbeassigneda“pass”number.Keycardswiththe
same“pass”numberswouldhaveaccesstothelocks.Thepassnumberfeaturecanbeautomatically
encoded,orselectedbytheuserwhenthekeycardismade.
Lockswiththe“pass”featurecanalsobeprogrammedtoallowthepasskeycardstofunctiononlyduringcertain
hoursoftheday.
InvalidKeycardShutdown
Ifteninvalidkeycardsareusedinalockinarow,thelockwillautomaticallyshutdownforonetotwominutes.No
indicatorlightswillbedisplayedduringthisperiod.Afteronetotwominutes,ifanotherinvalidkeycardisused,it
willcausethelocktoonceagainshutdown.Theuseofavalidkeycardwillterminatetheshutdownmode.
LEDDiagnostics
Ifakeycarddoesnotworkinalock,LEDdiagnosticscanbeactivatedbytheuseofthePPKandLEDDiagnostics
keycards.AfteractivatingtheLEDdiagnostics,thekeycardthatdidnotworkwillcausethelightindicatorsto
displayanerrorcodethatindicatesthereasonthekeycarddidnotwork.Iftheinsertedkeycardisavalidkeycard,
theindicatorlightswilldisplaythenormallightsandthekeycardwillworknormally.LEDdiagnosticscanbe
terminatedbyinsertingtheLEDDiagnosticskeycard,orwillterminateautomaticallyaftertwominutes.
LowBatteryandClockReset
Ifthelock’sbatteriesarelow,oriftheclockneedstobereset,aredindicatorlightwillflashwhenacorrect
keycardisused.Ifthebatteryislow,theredlightwillflashalternatelywiththenormallightswhenthekeycardis
used.Iftheclockneedstobereset,theredlightwillflashsimultaneouslywiththenormalindicatorlightswhen
thekeycardisused.
Eachkeycardisalsoprogrammedtoindicatewhetherornotitwillbeaffectedbythelowbatteryorclockreset
condition.
HassledThefirsttimethekeycardisused,thelockwilldisplayonlytheredindicatorlightandwillnot
allowentryintotheroom.Whenthekeycardisusedagain,itwilldisplaythenormalindicatorlights,along
withtheredindicatorlight,andthelatchingmechanismwillbereleased.
LockedOutThefirstandeachsubsequenttimethekeycardisused,theredindicatorlightwillflash,but
entrytotheroomisdenied,regardlessofthenumberoftimesthekeycardisusedinthelock.
NotHassledandNotLockedOutWhenthekeycardisused,itwilldisplaythenormalindicatorlights,
alongwiththeredindicatorlight,andthelatchingmechanismwillbereleased.
Whentheclockisreset,orthebatterychanged,thekeycardswilloperatenormally.
© SAFLOK
Page5of1606_11

Table of Contents