PIBasicErrorsinProgramCyclecontinued
Code Description
135 StandardandSpecialKeys:Keyistoonew,levelhaslimitedsequencerangeandkey’ssequence
numberisbeyondthelock’skeydataandrange.Makeandusearesequencekey,thentrythe
originalkeyagain.
136 StandardKey:Keyisalimitedusekeyandhasalreadybeenusedthemaximumnumberoftimes.
Replacekeywithanewkey.
137 StandardKey:Thekeyisanewkeybutthedoorisdeadboltedandthenewkeycannotbe
accepted.Ifkeyisforanewguest,theroomisstilloccupied.Assignnewguesttoanotherroom.
138 StandardKey:ThekeyisanewkeyandcannotbeacceptedsincethelockisinMode3Override.
Usethecurrentkeyfromanothermasterlevelinstead.
139 StandardKey:Thekey’sexpirationcan’tbevalidatedbecausethelock’sclockdateneeds
resetting.Resetthelock’sclock.SeeSection3.
140 StandardandSpecialKeys:Thekey’sexpirationcan’tbevalidatedbecausethelock’sclocktime
needsresetting.Resetthelock’sclock.SeeSection5.
141 AllKeys:Thekeyisexpiredbasedonthelock’sclockdateandtime.Replacekeywithaduplicate
keywithalaterexpirationdateandtime.
142 Standard,Special&PPKKeys:Thekeyisinvalidonthisdayofweekorthelocklevelisnon
operatingonthisdayofweek.
143 Standard,Special&PPKKeys:Thelockcannotdetermineifthelevelshouldoperateorthekeyis
validonthisdayoftheweekbecausethelock’sclockdateneedsresetting.Resetthelock’sclock.
SeeSection5.
144 StandardandPPKKeys:Thelockcannotdetermineiftheshiftkeyisvalidatthistimebecause
thelock’sclocktimeneedsresetting.Resetthelock’sclock.SeeSection5.
145 StandardandPPKKeys:Theshiftkeyisnotvalidatthistimeofday.
146 StandardKey:Thelock’slevelispass,butitonlyoperatesduringcertainhoursofthedayandthe
lockcannotdetermineifthelevelshouldoperateatthistimebecausethelock’sclocktimeneeds
resetting.Resetthelock’sclock.SeeSection5.
147 StandardKey:Thelock’slevelispassanditsoperationaltimesvarybydayofweekbutthelock
cannotdeterminewhenthelevelshouldoperatebecausethelock’sclockdateneedsresetting.
Resetthelock’sclock.SeeSection5.
148 StandardKey:Thelock’slevelispassbutitonlyoperatesduringcertainhoursofthedayand
doesnotoperateatthistimeofday.
149 StandardKey:Keyiscurrentbutkey’slevelisinhibited.Replacekeywithanewkey.