© SAFLOK Page31of34 06/11
PIBasicErrorsinProgramCyclecontinued
Code Description
177 PIKeys:ThePPKorSPKkeyusedtostarttheprogramcyclewasnotauthorizedtoprogramthisPI
keyintothelock.UseaPPKorSPKwiththeproperauthorization.RefertoSection5.
178 StandardKey:Thekeyisnewandisidentifiedasapreregkeywhichwillnotworkuntilitscheck
indateandtime.Ifdesired,replacekeywithanewkey.
179 DisplayKey:Keyhasaninvalidfunction(greaterthan3).ContactSAFLOKforassistance.
180 LPIRequest:KeyappearstobeanLPIrequestbutlockisnotinLPImode.ContactSAFLOKfor
assistance.
181 LPIRequest:KeyhasaninvalidLPIfunction(notequalto07or128131).ContactSAFLOKfor
assistance.
182 PIBasic:PIkeymustprograminthehardwareandcommunicationmodewhenthelockisin
Mode1FormattedandUnprogrammed.ContactSAFLOKforassistance.
183 StandardKey:WhenthelockisintheLPImode,thelockwillnotallowthedoortobeopened
(openingkey)unlessthelock’sbatteriesarelow,thelockisinMode3Overrideorthelockisin
Mode5CriticalLockingProblem.ContactSAFLOKforassistance.
184 PPKKey:ThekeyisnewbutthelockisinMode4E2Disabledandnewkeysarenotaccepted.
ContactSAFLOKforassistance.
185 DisplayKey:WhenthelockisintheLPImode,thelockwillnotacceptDisplaykeyssincetheLPI
cannotreadthem.ContactSAFLOKforassistance.
186 StandardKey:Thekeyisaccepted,butisnonopeningandwillnotopenthedoor.
187 StatusKey:Inaprogrammingcycle,theStatuskeywasusedafterPIkeys,butitmustbethefirst
andonlykeyaftertheprogramcyclebegins.ToprograminaStatusKey,usethePPKorSPKkey
followedbytheStatuskey.
188 AllKeys:ThelockisinTestModeindicatingfatalproblemoccurredandthelockshouldbe
returnedtosupplier.OnlyLPIinterrogationsareallowed.Thelockmustbedrilledtoaccessthe
room.
189 StandardKey:Thekeyisanopeningkeybutthelockfoundthehardwareswitchesindicateda
motormightbeconnectedeventhoughthelock’shardwaremodeindicatesasolenoidis
connected.Openingkeyswillnotbeaccepteduntilthelock’shardwaremodeisprogrammedto
matchtheswitchindications.ContactSAFLOKforassistance
190 StatusKey:LEDDiagnosticsKey.TheLEDDiagnosticskeydidnotdoanything.Ifyouweretrying
toturnLEDDiagnosticson,youmustusethePPKkeyfirst.IfyouweretryingtoturnLED
Diagnosticsoff,nofurtheractionisrequiredsinceLEDDiagnosticsisalreadyoff.