Page #6 background imageLoading...
Page #6 background image
System6000
TM
TrainingandReferenceManual
1.2System6000Components(Continued)
SAFLOKLocks
SeverallockmodelsareavailabletofunctionwithSystem6000.Saflokhastwotypesoflocks
whichusedifferentkeymedia.ThefirsttypeisaMagneticreaderlockthatfunctionsin
conjunctionwithMagstripekeys.ThesecondlocktypeisRFIDlocksthatuseMifareRFIDkeys
andFOB’s.
Thelockscontainacircuitboard,whichisconnectedtoabatterypack.Whenaproperly
encodedkeycardisusedatthelock,thecircuitboardreadsthecodeonthekeycardandsends
anelectronicsignaltoreleasethelockingmechanism.Theguestthenhasapproximately56
secondstoturnthelockhandleandentertheroom.Ifthelockhandleisnotturnedwithinthe
allottedtime,thelockingmechanismwillautomaticallyreturntothelockedposition.Theguest
willthenreinsertthemagstripekeycardorpresenttheRFIDkeytogainaccesstotheroom.
MostSAFLOKlocksfeaturea1”steeldeadboltandathrowdeadlockinglatchboltwithanti
theftfeature.Whenthehandleisturnedfrominsidetheroom,apanicfeatureretractsboth
thelatchandthedeadbolt.WiththeautomaticdeadboltADB®feature,thelockshavean
automaticdeadboltfeaturethatprojectsa1”deadbolteachtimethedoorisreturnedtothe
closedposition,providingcontinuousdeadboltlatchingsecurity.Aprivacybuttonorswitchcan
beactivatedfrominsidetheroom,preventingpropertypersonnelfromenteringtheroom,
exceptinemergencies.
Keycards
Thekeycardisthemessengertothelock,andprovidesthelockwiththelockcoding
information.Thekeycardcarriesthecodeinformationprovidedbythecomputerandkeycard
encoder.Whenaproperlyencodedkeycardisinsertedorpresentedtothelockandremoved,
thelockcircuitboardupdatesthecodeinformationinitsmemory,renderingpreviouslyissued
keycardsinvalid.
EmergencyLockPowerSupply(ELPS)
The Emergency Lock Power Supply is used to restore battery power to a lock that has
insufficient internal battery power. When inserted into the lock, and inserting a cut valid
keycard, a lock with a dead battery can be activated. This capability eliminates the need to
forciblyremovealockfromadoorbecauseithaslostpower.Oncethedoorhasbeenopened,
thebatteriescanbereplaced.
LockProgrammerandInterrogator(LPI)InterfaceProbe/ELPSpoweroverride
TheLockProgrammerandInterrogatorInterfaceProbeservesasaninterfacebetweentheLPI
Deviceandthelock.Theprobecanbeusedtoprogramlocksortointerrogatealockwhenitis
necessarytoobtainahistoryofthekeycardsthatwereusedtoaccessthelock.Thesmartcard
probealsoallowsanemergencyoverrideoptionwhenadeadbatteryconditionoccursona
lock.Oncethedoorhasbeenopened,thebatteriescanbereplaced.
© SAFLOK
Page2of406_11

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kaba Saflok SYSTEM 6000 and is the answer not in the manual?

Kaba Saflok SYSTEM 6000 Specifications

General IconGeneral
BrandKaba
ModelSaflok SYSTEM 6000
CategoryControl Systems
LanguageEnglish