Wear close-fitting clothes and a hair net if necessary.
Make sure all covers and safety guards are in place and secured before re-starting.
Temperature
High temperatures are generated during compression. Touching hot components may cause inju‐
ries.
Avoid contact with hot components.
These include, for example, compressor airends or blocks, oil and compressed air lines, cool‐
ers, oil separator tanks, motors and machine heaters.
Wear protective clothing.
If welding is carried out on or near the machine, take adequate measures to prevent sparks or
heat from igniting oil vapors or parts of the machine.
Noise
The enclosure absorbs the machine noise to a tolerable level. This function will be effective only if
the enclosure is closed.
Operate the machine only with intact sound insulation.
Wear hearing protection if necessary.
The blowing-off of the safety relief valve can be particularly loud.
Operating fluids/materials
The used operating fluids and materials can cause adverse health effects. Suitable safety meas‐
ures must be taken in order to prevent injuries.
Strictly forbid fire, open flame and smoking.
Follow safety regulations when dealing with oils, lubricants and chemical substances.
Avoid contact with skin and eyes.
Do not inhale oil mist or vapor.
Do not eat or drink while handling cooling and lubricating fluids.
Keep suitable fire extinguishing agents ready for use.
Use only KAESER approved operating materials.
Unsuitable spare parts
Unsuitable spare parts compromise the safety of the machine.
Use only spare parts approved by the manufacturer for use in this machine.
Use only genuine KAESER replacement parts on pressure bearing parts.
Conversion or modification of the machine
Modifications, additions to and conversions of the machine or the controller can result in unpredict‐
able dangers.
Do not convert or modify the machine!
Obtain written approval by the manufacturer prior to any technical modification or expansion of
the machine, the controller, or the control programs.
3 Safety and Responsibility
3.5 Dangers
9_5875 33 USE
Operator Manual Screw Compressor
SM Tri-Voltage, SIGMA CONTROL 2
15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SM 10 and is the answer not in the manual?

KAESER SM 10 Specifications

General IconGeneral
BrandKAESER
ModelSM 10
CategoryAir Compressor
LanguageEnglish

Related product manuals