5. Take out the top cover of the
dispenser valve
6. Separate dispenser valve from sheave permanent seat, take out sheave and
disassemble microswitch.
7. Take out the sheave and
disassemble the microswitch
Note: when installing, the microswith with two lines should be in the upside and
the microswitch with three lines should be in the downside; the black side of the
upside microswitch should face down, the black side of the downside
microswitch should face up. The slot on the sheave should face to the connector
of the microswitch.
Note Take out the sheave
drive part according to the
arrow direction