ZEUS-VD INSTALLER’S MANUAL
9.7.2 LN remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;LN8=12;LN1=13;LN2=123;LN3=5;LN4=45;LN7=12;
If you want to get the confirmation SMS back then write “+” before SMS command:
;+LN8=12;LN1=13;LN2=123;LN3=5;LN4=45;LN7=12;
9.8 MAIN POWER LOST AND TELEPHONE NO. LINKING – LN5
Page
17
The ZEUS4-VD will send an SMS message in case when the main power has been lost. In this case
the ZEUS4-VD will send an SMS to user. The default SMS is “Main Power Lost”. You can also
program how many time the unit must be without power before sending this message. The default
time is 5 second (parameter MAIN).