MAXICAL
®
III 5511-229 GB/98.06/Rev. B1
42
c) Normal data 2:
-> / # 2 [300 BAUD]
<- Customer No., TA2, TL2, TA3, TL3, Alarm Limit, 0,
Prog. No., Config. No., Date
[1200 BAUD]
d) Read-out data:
-> / # 3 [300 BAUD]
<- Customer No., Target Date, Energy, Water, TA2, TA3,
AL, 0, 0
[1200 BAUD]
e) Data read-out of verification data:
-> / # 4 [300 BAUD]
<- Energy, Quick sum, Dt x k-factor, Water, Water
remainder 1, Water remainder 2, t
F
,t
R
, Prog.No.
[1200 BAUD]
f) Data read-out of daily data:
-> / # 5 [300 BAUD]
<- Customer No., Read-out date, Energy, Water, TA2,
TA3, Alarm Limit, Peak time, Peak Power/flow —
(hourly data)
[1200 BAUD]
<- Read-out date, Energy, Water, TA2, TA3, Alarm Limit,
Peak time, Peak Power/flow — (1 previous day)
.
.
<- Read-out date, Energy, Water, TA2, TA3, Alarm Limit,
Peak time, Peak Power/flow — (the previous 30 days)
<- Read-out date, Energy, Water, TA2, TA3, Alarm Limit,
Peak time, Peak Power/flow — (the previous 31 days)