EasyManua.ls Logo

Kamstrup MULTICAL 801 - Page 72

Kamstrup MULTICAL 801
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MULTICAL® 801
72
Kamstrup A/S · Technical Description · 5512-571_R1_GB_11_2016
7.2.2 Flow sensor coding
Installing the sensor it is important that both flow sensor and MULTICAL
are correctly programmed. The below-
mentioned table lists the most frequently used flow sensor codes:
Number of decimals in display
CCC
No.
Pre-
counter
Flow
factor
MWh
Gcal
GJ m³
[ton]
m³/h MW l/imp Imp./l
Qp range [m³/h]
Qs
[m³/h]
Type Flow
sensor
201 100 235926 2 1 1 1 2 1 1 10…100
75 FUS380
DN50-65
N
202 40 589815 2 1 1 1 2 2.5 0.4 40…200
240 FUS380
DN80-100
N
203 400 589815 1 0 0 1 2 2.5 0.4 100…400
500 FUS380
DN125
N
204 100 235926 1 0 0 0 1 10 0.1 150…1200
1600 FUS380
DN150-250
N
205 20 1179630 1 0 0 0 1 50 0.02 500…3000
3600 FUS380
DN300-400
N
206 100 2359260 0 x10
x10
0 1 100 0.01 1400…18000
36000 FUS380
DN500-1200
N
Table 3

Table of Contents