Waste water, e.g. from heat recovery systems
Waste water from swimming pools (increased chlorine concentration)
Waste water with salt content (e.g. seawater)
4.8 Collecting tank
The collecting tank is designed for unpressurised operation: The waste water is
stored in the tank in unpressurised condition and is then pumped into the sewer
system.
The table below indicates the effective tank volume as a function of the inlet nozzle
level H in mm.
Table 8: Effective tank volume as a function of inlet nozzle level
Size Total volume Effective volume as a function of inlet
nozzle level
[litres]
H = 180 mm
[litres]
H = 250 mm
[litres]
Vertical
[litres]
U1.60 60 20 - 30
U2.100 100 35 47 65
US2.100 100 30 42 65
UZ1.150 150 70 100 110
UZS1.150 150 - 100 110
4.9 Noise characteristics
The sound pressure level depends on the local conditions and the duty point and is in
the region of <70 dB(A).
4.10 Scope of supply
Depending on the model, the following items are included in the scope of supply:
▪ Sewage lifting unit consisting of:
–
Gas, odour and water-tight collecting tank made of impact-resistant plastic
material, with fully floodable submersible motor pump(s)
▪ Flexible hose connections and hose clips
▪ Check valve
▪ Y-pipe
▪ Analog level sensor
▪ Electronic control unit
4.11 Dimensions and weights
For dimensions and weights refer to the outline drawing of the lifting unit.
Table 9: Dimensions and weights
Max. current
[A]
Size HxWxD
[mm] [kg]
Type BC
10 400 x 278 x 135 3
Type BS1
10 400 x 300 x 155 10
14 600 x 400 x 200 14
18 600 x 400 x 200 14
23 600 x 400 x 200 14
25 600 x 400 x 200 14
40 760 x 600 x 210 18
63 760 x 600 x 210 18
Type BS2
10 400 x 300 x 155 16
Lifting unit
Control unit
4 Description