EasyManuals Logo

KEB COMBIVERT F5 Operation Manual

KEB COMBIVERT F5
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
39
Control Circuit - STO
An optional Safe Torque Off (STO) control card can be used with the F5
drive. The safety control card provides Safe Torque Off functionality in ac-
cordance to IEC 61800-5-2.
These inverter units with a safety control card can be identied by the KEB
part number and will have a “K” in the 5th placeholder (e.g. xx.F5.Kxx-xxxx)
The KEB STO card meets performance levels (ISO13849-1) and SIL 3 (IEC
61508 and IEC62061).
For more information on the control card, see KEB document (00F5NES-
K000).
2.2. Control Circuit
- STO

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)