Drive Faults
Error/Message Alt. /
(NUM)
Description Cause/Solution/Troubleshoot
Error Overload EOL
(16)
Time dependent
overload (See
overload curves
under Technical
Data, Section
2.9).
Error cannot be
reset until display
shows E.nOL!
Cause of excessive motor overload may include:
Excessive current.
Verify correct motor data.
Verify correct encoder settings including:
LE02 Encoder Pulse Number
LE03 Swap Encoder Channels (A/B setting)
LE06 Encoder Pole position for PM Synchronous
Motors.
High mechanical load/issues (friction).