EasyManuals Logo

KEB COMBIVERT F5 Operation Manual

KEB COMBIVERT F5
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
99
Drive Faults
Error/Message Alt. /
(NUM)
Description Cause/Solution/Troubleshoot
Error Overload EOL
(16)
Time dependent
overload (See
overload curves
under Technical
Data, Section
2.9).
Error cannot be
reset until display
shows E.nOL!
Cause of excessive motor overload may include:
Excessive current.
Verify correct motor data.
Verify correct encoder settings including:
LE02 Encoder Pulse Number
LE03 Swap Encoder Channels (A/B setting)
LE06 Encoder Pole position for PM Synchronous
Motors.
High mechanical load/issues (friction).

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)