EasyManua.ls Logo

Keba KeContact P20 - Page 26

Keba KeContact P20
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation KeContact P20
26 Installation manual, Version: 1.41 / Article no.: 90064
© KEBA 2012-2013
Connecting the mains supply line (example)
Connecting the mains supply line
Shorten the connection wires to the
appropriate length; these should be kept
as short as possible.
The PE conductor must be longer than
the remaining conductors!
Strip approx.12 mm from the connection
wires.
Wire end sleeves are recommended for
finely stranded wires.
Perform the connection of the mains
supply line [L1], [L2], [L3], [N] and [PE].
Observe which phase conductor you
connect to terminal [L1] if several
charging stations are installed in a
network (DIP-switch settings for load
management).
1-phase connection
It is also possible to perform a 1-phase connec-
tion of the charging station. Use the terminals
[L1],[N] and [PE].
Supply terminals
Supply terminals
The supply terminals are designed as spring-
type terminals.
Insert the flathead screwdriver (blade with
5.5 mm) into the supply terminal as
shown on the picture.
Terminal data:
- inflexible (min.-max): 0.2 – 16 mm²
- flexible (min.-max): 0.2 – 16 mm²
- AWG (min.-max): 24 – 6
- flexible (min.-max) with wire end sleeve:
Without/with plastic sleeve
0.25 – 10 / 0.25 – 10 mm²
- Stripping length: 12 mm
- Flathead screwdriver: 5.5 mm