KeContact P20 Installation
Installation manual, Version: 1.41 / Article no.: 90064 31
© KEBA 2012-2013
Color coding:
According to the used wiring standard in the building, the contacts are wired according to
TIA-568A/B for 100BaseT:
Pin -568A
Pair
-568B
Pair
-568A
Color
-568B
Color
1 (Tx+) 3 2
white/green stripe white/orange stripe
2 (Tx−) 3 2
green/white stripe
or green
orange/white stripe or
orange
3 (Rx+) 2 3
white/orange stripe white/green stripe
4 (Rx−) 2 3
orange/white stripe
or orange
green/white stripe or
green
Terminal data:
Category Wire diameter Insulation diameter
0.36 mm (AWG 27)
0.7 – 0.75 mm Inflexible cable
Cat 5e / Cat6 STP
0.4 – 0,64 mm
(AWG 26 – AWG 22)
0.7 – 1,4 mm
Cat 6 STP 0.51 – 0,81 mm
(AWG 24 – AWG 20)
1.0 – 1,4 mm
Flexible cable
Cat 5e / Cat 6 STP
7 x 0.2 mm
(AWG 24)
1.1 – 1,4 mm
LSA+® insertion tool
LSA+® insertion tool
Original KRONE insertion tool with solder-free
and stripping-free connection of the wires and
simultaneous trimming of the residual lengths.