APPENDIX
Appendix 1: Fahrenheit and Celsius Reference Sheet
Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32
Table 35—Set Temperature
Fahrenheit Display
Temperature (
_F)
Fahrenheit (_F) Celsius (_C)
Fahrenheit Display
Temperature (
_F)
Fahrenheit (_F) Celsius (_C)
Fahrenheit Display
Temperature (
_F)
Fahrenheit (_F) Celsius (_C)
61 60.8 16 69/70 69.8 21 78/79 78.8 26
62/63 62.6 17 71/72 71.6 22 80/81 80.6 27
64/65 64.4 18 73/74 73.4 23 82/83 82.4 28
66/67 66.2 19 75/76 75.0 24 84/85 84.2 29
68 68 20 77 77 25 86 86 30
Table 36—Ambient Temperature
Fahrenheit Display
Temperature (
_F)
Fahrenheit (_F) Celsius (_C)
Fahrenheit Display
Temperature (
_F)
Fahrenheit (_F) Celsius (_C)
Fahrenheit Display
Temperature (
_F)
Fahrenheit (_F) Celsius (_C)
32/33 32 0 55/26 55.4 13 79/80 78.8 26
34/35 33.8 1 57/58 57.2 14 81 80.6 27
36 35.6 2 59/60 59 15 82/83 82.4 28
37/38 37.4 3 61/62 60.8 16 84/85 84.2 29
39/40 39.2 4 63 62.6 17 86/87 86 30
41/42 41 5 64/65 64.4 18 88/89 87.8 31
43/44 42.8 6 66/67 66.2 19 90 89.6 32
45 44.6 7 68/69 68 20 91/92 91.4 33
46/47 46.4 8 70/71 69.8 21 93/94 93.2 34
48/49 48.2 9 72 71.6 22 95/96 95 35
50/51 50 10 73/74 73.4 23 97/98 96.8 36
52/23 51.8 11 75/76 75.2 24 99 98.6 37
54 53.6 12 77/78 77 25
Appendix 2: Connection Pipe Configuration
1. Standard length of the connection pipe
S .2 in (5m), .29 in (7.5m), .31 in (8m)
2. Minimum length of the connection pipe is .12 in (3m).
3. Maximum length of the connection pipe and maximum height
difference.
4. The additional refrigerant oil and refrigerant charging required
after prolonging connection pipe.
S After the connection pipe length is lengthened for .39 in
(10m) at the basis of the standard length, add 5ml of
refrigerant oil for each additional .2 in (5m) of connection
pipe.
S The calculation method of additional refrigerant charging
amount (on the basis of liquid pipe):
S When the connection pipe length is above .2 in (5m), add
refrigerant according to the prolonged length of liquid pipe.
The additional refrigerant charging amount per meter is
different according to the diameter of liquid pipe. Review the
following table.
S Additional refrigerant charging amount = prolonged length of
liquid pipe X additional refrigerant charging amount per meter.