To do so, please proceed as follows:
3. Press the rotary switch (Pos. 6) for approx. 3 seconds until “SFC” appears.
4. Press the rotary switch briefly to access the filter cleaning setting.
5. Turn the rotary switch to the right. The setting value changes from 0 to
1. (1 = start of the cleaning)
6. The side channel compressor reduces the extraction capacity, followed
by filter cleaning for approx. 15 seconds. The filter cleaning time is
running on the digital LED display.
7. If the rotary switch (Pos. 6) is turned to the left during filter cleaning,
filter cleaning stops immediately and the product switches back to the
previously set operating extraction capacity.
6.3 Commissioning
WARNING
Danger due to faulty product condition.
The product must be fully installed before commissioning begins. All
doors must be closed and the necessary connections must have been
made.
1. Connect the power supply connection cable of the product to the on-
site power supply.
2. Switch on the product by pressing the On/Off switch.
3. The fan starts and the green signal light of the On/Off switch indicates
trouble-free operation.
If there is a fault, please refer to the "Troubleshooting" chapter.