Page #12 background image
Service manual Master S 400 and 500
Version 1.1
5.9.2014
10
Kemppi Oy
3.6. Setup functions and error codes
3.6.1. Setup functions and menu
Setup can be entered by pressing “Remote” button as long as text “Set” appears in the display.
Parameters can be browsed with potentiometer and by pressing shortly “Remote” button parameter value
can be adjusted by potentiometer. Short press again exits the parameter value adjustment and
potentiometer browses parameters again. Long pressing the “Remote“ button exits from the setup and
saves values.