Setup functions
Electrode ignition pulse. -9=No pulse, 0=Max pulse0-9 … 0t
Arc dynamics (Arc Force)0-3 … 5S
Maximum setting of post-gas time.30s15 … 99so
Maximum setting of pre-gas time.10.0s5.0 … 20.0sL
J
h
F
E
d
C
B
A
Name on
display
1.0s
0s
0
20%
1
0
0
0
Factory
setting
Forced stop during downslope with a brief pressing of the switch. 1=On, 0=Off0 or 1
Alternative switch logic. 0=4T LOG, 1=Minilog,( 2=4T-LOG+Minilog, 3= Minilog+ search arc )0,1,2 or 3
Start current level as % of the welding current.5 … 40%
Restore factory settings. 1=Restore, 0=No restore0 or 1
Minimum setting of pre-gas time.0.0 … 2.0s
Minimum setting of post-gas time.
Open-circuit voltage selection. 1=30V (VRD), 0=95V
End current level selection. 1=5A, 0=15%
Description
0.0 … 10.0s
Parameter
value range
0 or 1
0 or 1
( Available from program version 0A7 )