34 KXS_KXG-TM-BA_IA-e-1932
10.3 Automatic adding-up
With this function the individual weighing values are automatically added into the
summation memory without pressing a key when the balance is unloaded and edited,
when an optional printer is connected.
Menu setting:
P2 COM
MODE
AUTO““, see chap. 11
Add up:
Place load A.
After completion of the stability control, the weight value will be printed and added
to the summation memory.
Remove the weighed good. More weighed goods can only be added when the
display ≤ zero.
Place good to be weighed B.
After completion of the stability control, the weight value will be printed and added
to the summation memory. Number of weighings, followed by the total weight will
be displayed for 2 sec.
Add more weighed goods as described before.
Please note that the weighing system must be unloaded between the individual
weighing procedures.
This process may be repeated 99 times or till such time as the capacity of the
weighing system has been exhausted.
For how to display and delete weighing data as well as sample logs see chap. 10.2