46 KXS_KXG-TM-BA_IA-e-1932
11.1 Overview non-verified weighing systems
(Adjustment switch in position <Adj>, see chap. 7.9)
Menu block
Main menu
Menu item
Submenu
Available settings / explanation
P0 ChK
Weighing with
tolerance range
SEt h Upper limit value „Tolerance check weighing“, input see
chap. 10.5.1
SEt L Lower limit value „Tolerance check weighing“, input see
chap. 10.5.1
PCS h
Upper limit value „Tolerance check counting“, input
see chap. 10.5.2
PCS L
Lower limit value „Tolerance check counting“, input
see chap. 10.5.2
bEEP no
Acoustic signal for weighing with tolerance range
switched off
oK*
Acoustic signal when weighed load is within
tolerance limits
nG
Acoustic signal when weighed load is beyond
tolerance limits
P1 rEF
Zero point
settings
A2n0 Automatic zero setting range, digits selectable (0* 9 d)
0Auto Switch-on zero setting range
Load range where the display after switching-on the
balance is set to zero.
Selectable 0, 2, 5, 10*, 20, 30, 50, 100 %
0rAGE Manual zero setting range
Load range by setting the display to zero after pressing the
ZERO-key.
Selectable 0, 2*, 4, 10 , 20* , 50, 100%.
0rECr While the function is enabled the last zero point will be
saved. After switching the appliance off and on or after a
power failure the equipment with the stored zero point
continues to work. Selectable on / off*
0tACE
Auto Zero function, selectable <on* / off>
While the scale is unloaded minor weight fluctuations will
be corrected automatically.
In the event that small quantities are removed or added to
the material to be weighed, incorrect weighing results can
be displayed due to the “stability compensation“.
(Example: Slowly draining fluids from a container on the
balance).
When apportioning involves small variations of weight, it is
advisable to switch off this function.
FiL Filter settings, selectable 0* - 9
< 0 >: Calm and stable environment
< 9 >: Busy environment