Functions and Specifications
3.6 Thermal Management
Table 19: Thermal management
Feature Rating or standard
Normal state
No restrictions.
T ≤ 70 °C
Overheat state 1
In the V5CAS and MCAS direct line operation modes,
new calls are possible only for high priority subscribers.
Ongoing calls are not affected.
In all other operation modes new calls are possible with-
out restriction.
T
ON
> 70 °C
T
OFF
< 68 °C
Overheat state 2
All ongoing calls are immediately stopped.
T
ON
> 85 °C
T
OFF
< 83 °C