page 40 of 94© KEYMILE December 2015 EN/LZTBU 372 129/1 RC
94
Functional Description
Please note:
It is not possible to set two identical CAS patterns for the signalling of one
direction.
In the CAS pattern comparison, a “x” in a CAS pattern from the exchange
counts for “0” and “1”, e.g. 1101 and 1x01 are not allowed.
Please note:
Signalling patterns with all “0” or all “1” are not allowed.
In the Phone-Exchange mode of operation the
Blocked port line feed function is fix disabled,
Metering pulse function towards the subscriber can be enabled or disa-
bled,
Pulse on answer function is disabled,
Polarity reversal function towards the subscriber can be enabled or disa-
bled.
1 0 1 1 Metering pulse -
1 1 0 1 Ringing -
Table 31: Phone-Exchange mode default signalling (continued)
CAS bit State
a b c d from exchange towards exchange