Keyscan Inc. Technical Guide (PC109x - 07.15)
95
Important - Circuit Board Function Revisions
The following functions on PC1097 version and higher control boards are programmable via the Client
software:
Reader configuration (formerly jumper J3)
Reader LED lock state (formerly J16)
Temporary card countdown (formerly J16)
Accessibility HC relay all cards enabled (formerly J16)
End-of-line supervision mode (formerly J18)
Reader lockdown LED mode (formerly J18)
You require the following Keyscan software versions:
Aurora version 1.0.1.0 or higher
System VII version 7.0.19 or higher
Vantage version 8.1.18 or higher
Circuit Board Card Capacity
PC1097 and higher circuit boards are defaulted for 45,000 Aurora - and 32,000 System VII and Vantage -
card-storage capacity names not stored in ACU. Keyscan strongly advocates that either the dealer/installer
or the end-user schedule automatic database backups at regular intervals to safeguard all site and credential
holder data. The database backup and scheduling functions are located in the Client software. In the event
that the database is not backed up, the Disaster Recovery utility is unable to retrieve names from the access
control board.