Key press and display Result
VOLT:M LIST
VOLT 120
DWELL [0] .5
DWELL [1] .5
DWELL [2] .5
VOLT [0] 130
VOLT [1] 140
VOLT [2] 150
STEP AUTO
INIT:IMMED
List transients generate complex output sequences. When these
commands are sent, the voltage amplitude is sequentially stepped to
three levels upon receipt of a trigger, and then returns to the original
voltage level. The output remains at each list step for .5 seconds. The
values inside the brackets ([ ]) are the list index references. Use
Clear Entry to clear a list.