EasyManua.ls Logo

Keysight N6701C - Page 190

Keysight N6701C
430 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Exponential
Back to ARB Commands
[SOURce:]ARB:CURRent:EXPonential:END[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:CURRent:EXPonential:END[:LEVel]? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:VOLTage:EXPonential:END[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:VOLTage:EXPonential:END[:LEVel]? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:POWer:EXPonential:END[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:POWer:EXPonential:END[:LEVel]? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:RESISTANCE:EXPonential:END[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:RESISTANCE:EXPonential:END[:LEVel]? [MIN|MAX,] (@<chanlist>)
Specifies the ending current, voltage, power, or resistance level after the exponential waveform ends.
[SOURce:]ARB:SEQuence:STEP:CURRent:EXPonential:END[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:EXPonential:END[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:EXPonential:END[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:EXPonential:END[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:EXPonential:END[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:EXPonential:END[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:EXPonential:END[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:EXPonential:END[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the ending current, voltage, power, or resistance level after the exponential waveform ends
for Arb sequence steps.
Parameter Typical Return
Current: 0 - maximum|MIN|MAX, *RST MIN
Voltage: 0 - maximum|MIN|MAX, *RST MIN
Power: 0 - maximum|MIN|MAX, *RST MIN
Resistance: 0 - maximum|MIN|MAX, *RST MIN
Values are range and module-rating dependent.
<end value>
Step 0 - 99, *RST 0 (none)
Programs an end level current: ARB:CURR:EXP:END 1,(@1)
Programs an end level voltage: ARB:VOLT:EXP:END 20,(@1)
Programs an end level power: ARB:POW:EXP:END 50,(@1)
Programs an end level resistance: ARB:RESISTANCE:EXP:END 100,(@1)
Programs an end current for step 0: ARB:SEQ:STEP:CURR:EXP:END 1, 0,(@1)