Number of Slots | 4 |
---|---|
Total System Power | 600 W |
Power Rating | 600 W |
Programming Interface | SCPI |
Type | Modular Power System |
Maximum Power per Slot | 300 W |
Output Power | Varies depending on modules installed (up to 300W per channel with appropriate modules) |
Output Voltage Range | Varies depending on modules installed (up to 60 V) |
Output Current Range | Varies depending on modules installed (up to 20 A) |
Programming Resolution | 1 mV / 1 mA |
Voltage Resolution | Varies depending on modules installed, up to 1 mV |
Current Resolution | Depends on module |
Voltage Accuracy | Depends on module |
Current Accuracy | Varies depending on modules installed |
Ripple and Noise | Depends on module |
Display | LCD |
Interface | GPIB, LAN, USB |
Dimensions | 88 mm H x 425.5 mm W x 497 mm D (3.46 in x 16.75 in x 19.57 in) |
DC Voltage | Varies depending on modules installed (up to 60 V) |
DC Current | Varies depending on modules installed (up to 20 A) |
Covers copyright, warranty, and legal notices pertaining to the manual and product.
Explains various hazard symbols used in the manual, including WARNING and CAUTION notices.
Lists general safety precautions that must be observed during instrument operation.
Lists SCPI commands for quick reference, categorized by function and subsystem.
Lists the supplemental characteristics and technical specifications of the N6700 series mainframes.
Provides detailed instructions for installing the mainframe, including module installation and rack mounting.
Explains how to safely connect the instrument's power cord to the AC input.
Covers basic operations like turning the unit on, setting voltage/current, and enabling outputs.
Details how to program output settings like voltage, current, resistance, and mode.
Details how to configure and use various output protection functions like OVP, OCP, and OT.
Explains SCPI basics, command types, keywords, queries, and syntax conventions.
Lists and explains SCPI error codes and their meanings for troubleshooting.
Lists required test equipment and recommended models for verification and calibration procedures.
Outlines procedures to verify the system operates normally and meets published specifications.
Provides calibration procedures for various power modules, including voltage and current calibration.
Details procedures for disassembling the instrument, including ESD precautions and required tools.
Offers guidance on diagnosing and resolving instrument issues, including preliminary checks and overall troubleshooting steps.