Compatibility With A and B Version MPS
Persona Commands
New Feature Comparison With A and B MPS Mainframes
The Persona commands described in this section are provided for compatibility with the existing
N6700B, N6701A, and N6702A Modular Power System (MPS). This section also compares the new
features to the previous A and B MPS Mainframes.
Persona Commands
Persona commands are provided to allow users to change the programmatic identity of the N6700C
series mainframes back to the "A" or "B" version mainframes for code compatibility. The manufacturer
string can also be changed for code compatibility. The persona commands are non-volatile.
Model Number
The following list documents the model number compatibility:
N6700C is compatible with N6700B
N6701C is compatiblewith N6701A
N6702C is compatiblewith N6702A
To change the model number ID of an N6700C to N6700B:
SYST:PERS:MOD "N6700B"
To return the model number to the factory shipped setting:
SYST:PERS:MOD:DEF
Manufacturer ID
The following list documents the manufacturer compatibility:
Keysight Technologies is compatible with Agilent Technologies
To change the manufacturer ID to Agilent Technologies:
SYST:PERS:MAN Agilent Technologies
To return the manufacturer to the factory shipped setting:
SYST:PERS:MAN:DEF