Front Panel Menu Reference SCPI Command
Select Output\Settings\Resistance.
Enter a resistance value. Then press Select.
To setthe output resistanceto 60 Ω:
RES 60,(@1)
You can manually select a lower resistance range if you need better output resolution. The following
ranges can be selected:
N6791A N6792A
High resistance range from 30 Ω to 8 kΩ from 15 Ω to 8 kΩ
Medium resistance range from 2 Ω to 100 Ω from 2 Ω to 100 Ω
Low resistance range from 0.08 Ω to 3 Ω from 0.04 Ω to 3 Ω
Front Panel Menu Reference SCPI Command
Select Output\Settings\Resistance.
Select a lower range. Then press Select.
To selectthe lower range, program a value that
falls within the range:
RES:RANG 1,(@1)
When changing ranges, the load input will be turned off, then back on again.
Set the Output Power
For Keysight N679xA load modules , the following commands program the input power
limit. The maximum programmable output power is either 100 W or 200 W, depending on which load
module is being programmed.
The power selection must previously be selected under Output Mode.
Front Panel Menu Reference SCPI Command
Select Output\Settings\Power.
Enter a Power Limitvalue. Then press Select.
To setthe inout power to 50 W:
POW 50,(@1)
You can also select a lower power range if you need better output resolution. The following ranges
can be selected:
N6791A N6792A
High power range from 0.3 W to 100 W from 0.5 W to 200 W
Low power range from 0.04 W to 10 W from 0.1 W to 20 W
Keysight N6700C Operating and Service Guide 97