Characteristic Keysight N6700C, N6701C, N6702C
Interface Capabilities
LXI Core 2011:
USB 2.0 (USB-TMC488):
10/100/1000 LAN:
Web server:
GPIB:
10/100/1000 Base-T Ethernet(Sockets, VXI-11 protocol, Web interface)
Requires Keysight IO Library version M.01.01 or 14.0 and up
Requires Keysight IO Library version L.01.01 or 14.0 and up
Requires a Web browser
SCPI - 1993, IEEE 488.2 compliant interface
Regulatory Compliance:
EMC:
Safety:
Complies with European EMC Directive for test and measurement products:
IEC/EN 61326-1; CISPR 11, Group 1, class A; AS/NZS CISPR 11; ICES/NMB-001
Complies with Australian standard and carries C-Tick mark
This ISM device complies with Canadian ICES-001
Cet appareil ISM est conforme à la norme NMB-001 du Canada
Complies with European Low Voltage Directive and carries the CE-marking.
Conforms to US and Canadian safety regulations.
Environmental
Operating environment:
Temperature range:
Relative humidity:
Altitude:
Storage temperature:
Indoor use, installation category II (for AC input), pollution degree 2
0°C to 55°C (output current is derated 1% per °C above 40°C
Up to 95% (non-condensing)
Up to 2000 meters
-30°C to 70°C
Acoustic Noise Declaration
This statement is provided to
comply with the requirements
of the German Sound Emission
Directive, from 18 January 1991
Sound Pressure Lp <70 dB(A), At Operator Position, Normal Operation, According to EN 27779
(Type Test).
Schalldruckpegel Lp <70 dB(A), Am Arbeitsplatz, Normaler Betrieb, Nach EN 27779 (Typ-
prüfung).
Output Terminal Isolation: No output terminal may be more than 240 VDC from any other terminal or chassis ground.
N6781A/N6785A Note:
When using the AUX measurement input terminals on Models N6781A and N6785A, no output
or input terminal may be more than ±60 VDC from any other terminal or chassis ground.
AC Input
Input ratings:
Input ranges:
Power Consumption:
Power Factor (Note1):
Fuse:
~ 100 VAC – 240 VAC; 50/60/400Hz
86–264 VAC; 47–63Hz; 380–420 Hz
1000 VA (N6700C)
1440 VA (N6701C)
1440 VA (N6702C @ < 180 VAC input)
2200 VA (N6702C @ > 180 VAC input)
0.99 @ nominal input and rated power
Internal fuse - not customer accessible
N6702C Note:
AC mains circuits rated at100-180 VAC cannot supply enough current to power the N6702A
mainframe when operated atits full rated power. When connected to a 100-180 VAC mains,
internal circuits will limit the power available to modules to 600 W maximum.