EasyManua.ls Logo

Keysight N9000B - Page 552

Keysight N9000B
2852 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Spectrum Analyzer Mode
3.3 Channel Power Measurement
5G NR Mode Measurement Results
n Results Returned
1 or not
specified
Returns scalar results:
1 Channel Power A floating-point number representing the total channel power in the
specified integration bandwidth
2 PSD (Power
Spectral
Density)
The power in the specified unit bandwidth. The unit bandwidth is
selected by "PSD Unit" on page 642; either dBm/Hz or dBm/MHz
2 Returns floating point numbers that are the captured trace data of the power (in dBm/resolution BW) of the
signal for Trace 1. The frequency span of the captured trace data is specified by "Span" on page 627
3 Returns comma-separated scalar results, in the following order
# Item Unit
1 Total Power of Component Carrier 0 dBm
2 Total Power of Component Carrier 1 dBm
3 Total Power of Component Carrier 2 dBm
16 Total Power of Component Carrier 15 dBm
If the result is not available, NaN (9.91E+37) is returned
4 Returns comma-separated scalar results, in the following order. The unit bandwidth is selected by PSD
Unit in either dBm/Hz or dBm/MHz
# Item Unit
1 Total Power of Component Carrier 0 PSD Unit
2 Total Power of Component Carrier 1 PSD Unit
3 Total Power of Component Carrier 2 PSD Unit
16 Total Power of Component Carrier 15 PSD Unit
If the result is not available, NaN (9.91E+37) is returned
5 Returns floating point numbers that are the captured trace data of the power (in dBm/resolution BW) of the
signal for Trace 2. The frequency span of the captured trace data is specified by "Span" on page 627
6 Returns floating point numbers that are the captured trace data of the power (in dBm/resolution BW) of the
signal for Trace 3. The frequency span of the captured trace data is specified by Span
7 Returns Marker Table data as a series of comma separated values in the following form:
<Marker Number>,<Marker Trace>,<X>,<Y>,<Reserved>,<Reserved>
Only markers that are enabled are included. <Reserved> are returned as NaN (“Not a Number”, 9.91e+37).
The data is returned in the current sort order as displayed in the Marker Table