EasyManua.ls Logo

Keysight N9320B - Meas; Channel Power

Keysight N9320B
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Key Reference
Meas
122
Meas
In the Spectrum Analyzer mode (see MODE), Meas key displays
a menu for measurements such as adjacent channel power,
occupied bandwidth, channel power, spectrum emission mask
and TOI. Press Measure Off to turn the measurement off.
Channel Power
Channel Power measures the power and power spectral
density in the specified channel bandwidth. A white frame
on the display indicates the edge limits of the channel
bandwidth. The user must specify the center frequency,
reference level, and channel bandwidth to be used for the
measurement.
Figure 4-4 Channel Power Measurement
Avg Number
On Off
Specifies the number of measurement averages used when
calculating the measurement result with Avg Number (On). The
range is 1 to 1000. Use the knob, the arrow keys or the
numeric keypad to set the number. The average will be
displayed at the end of each sweep. Selecting Off disables
measurement averaging.
Key access: