173
Instrument Messages
Command Errors
Command Errors
The messages listed below are command errors, which are
saved into local registers.
-100 Command error
An unrecognized command or data type was encountered.
This message is used when the device cannot detect more
specifics described for errors - 101 to - 109.
-101 Invalid character
A syntactic element contains an invalid character.
-102 Syntax error
An unrecognized command or data type was encountered.
-103 Invalid separator
The parser was expecting a separator and encountered an
illegal character.
-104 Data type error
The parser recognized a data element that is not allowed.
-108 Parameter not allowed
More parameters were received than expected for the
header. For example, the *ESE common command only
accepts one parameter, so receiving *ESE 0,1 is not allowed
.
-109 Missing parameter
Fewer parameters were received than required for the
header. For example, the *ESE common command requires
one parameter, so receiving *ESE is not allowed.
-110 Command header error
An error was detected in the header. This message is used
when the device cannot detect more specifics described for
errors - 111 to - 119.