EasyManua.ls Logo

Kimo C310 - Page 8

Kimo C310
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unit – Modbus code : 7030 (channel 1)
7060 (channel 2)
7090 (channel 3)
7120 (channel 4)
List of units :
Field Unit Value Field Unit Value
None 0 None 0
Temperature
°C 16
Air velocity
m/s 64
°F 17 fpm 65
Hygrometry
%HR 32 km/h 66
G/Kg 33
Airflow
m3/h 80
Kj/KG 34 L/s 81
°C td 35 cfm 82
°F td 36 m3/s 83
m3/h 80
°C Tw 37 Combustion ppm 112
°F Tw 38
Electricity
mV 160
Pressure
kPa 50 V 161
inWg 51 µA 162
hPa 52 mA 163
mbar 53 A 164
mmHg 54
mmH2O 55
daPa 56
Pa 57
Example of a measurement at 24.2 °C :
Value : code 7010, real type (Most Significant Byte / Least Significant Byte)
Byte 3 Byte 4 Byte 1 Byte 2
b15 b16 b31 b24 b7 b0 b15 b8
0100 0001 1100 0001 1001 1001 1001 1010
Value : 24.2
Number of digits after the decimal point : code 7020, U8 type
Byte 1
b7 b0
0000 0001
Number of digits after the decimal point : 1
8